Controlled Flow Manual Resuscitators

Ventilation Timing Lights

 Timing Light Pair

Manual Ventilation Timing for CPR or Respiratory Arrest

Ventilation timing during CPR or respiratory arrest has been shown to be poorly performed, overly aggressive and potentially detrimental to patient survival.

Providing ventilations at too fast a rate, or with inspiration and expiration times that are too short, decreases venous return to the heart by stacking breaths, increasing and maintaining high intrathoracic pressures. It also risks increasing brain ischemia by decreasing carbon dioxide levels in the blood, causing peripheral cerebral vasoconstriction.

In the mask ventilated patient, high airway pressures and flows risk gastric insufflation and the subsequent aspiration of stomach contents.

The single-use O-Two Adult and PEDI Ventilation Timing Lights go one step further than other devices currently available. They not only provide timing for the initiation of the breath but also indicate the duration of the ventilation by remaining illuminated for the duration of the inspiratory time,. This provides a safe, slow delivery of the breath. The off phase provides adequate expiration time to avoid breath stacking.

Simple and easy to apply and use, the O-Two Adult and PEDI Ventilation Timing Lights are truly a flash of inspiration.

Note: Do not attempt to deliver the breath between compressions but provide the breath over the course of two to three compressions.

Instructions for Use

The O-Two Adult and PEDI Ventilation Timing Lights come with an adhesive backing with peel-off cover paper to allow the attachment of the light to manual resuscitators.

The ventilation timing light is activated by pulling the tab.

Ventilation Timing Lights-OnFollow the timing light by initiating the ventilation when the light turns on and slowly delivering the breath over the duration of the on time. Ventilation Timing Lights-OffWhen the light goes off, release the bag squeeze allowing the bag to refill and the patient to exhale.
  • Adult Ventilation Timing Light

    Adult Ventilator Timer-Activated

                       

    Specifications

    On time: 1.5 seconds
    Off time: 4.5 seconds
    Ventilation Rate: 10 breaths per minute
    Diameter: 30 mm (approx. 1.180 in)
    Weight: 3.6 g (approx. 0.007 lb)
    Battery type: Li-MnO2 (Lithium-manganese dioxide) coin battery
    Battery Shelf Life: 1 year
    Storage Temperature: -20 to 50°C (-4 to 122°F)
    Operating Temperature: -5 to 40°C (23 to 104°F)

    Part Number and Product Description

    01BM1000-CS Adult Ventilation Timing Light Individually packaged (Case of 50)
      Download PDF Spec. Sheet
  • PEDI Ventilation Timing Light

    Child Ventilator Timer-ActivatedVentilation timing during CPR or respiratory arrest has been shown to be poorly performed, overly aggressive and potentially detrimental to patient survival. Providing ventilations at too fast a rate, or with inspiration and expiration times that are too short, decreases venous return to the heart by stacking breaths, increasing and maintaining high intrathoracic pressures. It also risks increasing brain ischemia by decreasing carbon dioxide levels in the blood, causing peripheral cerebral vasoconstriction. In the mask ventilated patient, high airway pressures and flows risk gastric insufflation and the subsequent aspiration of stomach contents. The single-use PEDI Ventilation Timing Lights go one step further than other devices currently available. They not only provide timing for the initiation of the breath but also indicate the duration of the ventilation by  remaining illuminated for the duration of the inspiratory time,. This provides a safe, slow delivery of the breath. The off phase provides adequate expiration time to avoid breath stacking. Simple and easy to apply and use, the O-Two Adult and PEDI Ventilation Timing Lights are truly a "flash" of inspiration.  

    Specifications

    On time: 1.0 seconds
    Off time: 2.0 seconds
    Ventilation Rate: 20 breaths per minute
    Diameter: 30 mm (approx. 1.180 in)
    Weight: 3.6 g (approx. 0.007 lb)
    Battery type: Li-MnO2 (Lithium-manganese dioxide) coin battery
    Battery Shelf Life: 1 year
    Storage Temperature: -20 to 50°C (-4 to 122°F)
    Operating Temperature: -5 to 40°C (23 to 104°F)

    Part Number and Product Description

    01BM1500-CS Pedi Ventilation Timing Light Individually packaged (Case of 50)
        Download PDF Spec. Sheet

O-Two Medical Technologies Inc. reserves the right to change, modify, or update the product specifications, product data and product information contained herein at any time without prior notice.