  • Single Use CPAP

     

    Award winning, compact, low-flow, non-invasive ventilation for the respiratory distressed patient

    Continuous positive airway pressure (CPAP) has been proven to provide an effective method of treating respiratory distress from congestive heart failure (CHF). The use of CPAP is now being extended to other respiratory problems to provide symptom relief and avoid the need for intubation and ventilation of the patient as well as ICU admission.

    The O-Two single-use open CPAP delivery system provides incredibly accurate CPAP delivery for such a compact device. By minimizing the pressure drop on inspiration and the peak pressure on expiration, the O-Two single-use open CPAP delivery system produces a more uniform CPAP pressure throughout the respiratory cycle. This provides a lower work of breathing for the patient when compared to other, commonly used, prehospital devices.

    Easy to Use

    The adjustment of the CPAP level is achieved by adjusting the output flow from your oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting:

    An open system, the device allows unrestricted inspiratory flows, since the patient has access to ambient air.

    Nebulizer treatments can be provided in-line, with the nebulizer positioned between the facemask and the CPAP unit.

    A luer port is located on the device to attach a pressure gauge. However, the accuracy of the CPAP level at the fixed-flow settings noted on the device makes the use of a gauge unnecessary.

    The ambient air intake port and the location of the in-line oxygen hose are designed to eliminate the possibility of accidental occlusion, removing the risk of barotrauma due to the patient or rescuer inadvertently blocking the port.

    Ideal for the treatment of the respiratory impaired patient suffering from a range of obstructive pulmonary diseases, the O-Two CPAP system is a simple, cost-effective alternative to invasive ventilation and possible intensive care admissions.

    O-Two CPAP Advantages

    • Small and lightweight: Complete system weighs only four ounces (0.1 kg)
    • Low oxygen consumption: Only 8-25 L/min for 5-25 cmH2O of CPAP
    • Simple to use: Flow control adjustment to set CPAP level
    • Wide CPAP range: 5-25 cmH2O
    • No ambulance downtime in ER: Simply attach to the ER oxygen supply
    • Decreased work of breathing: Open circuit design imposes no work on the patient
    • Comfortable and secure head harness options: Soft, conforming Neoprene or  traditional "Full Crown" head harness
    • Small size: Fits into existing jump bags and storage compartments
    • Cost effective: Low purchase price and low oxygen consumption compared to other devices
    • Nebulizer kit: Allows nebulized medications to be provided during CPAP treatment
    • Available pressure manometer.

    Specifications

    [read more="Click here for Specifications" less="Read less"]

    CPAP range:1-25 cmH2O
    Required flow rate:3-25 L/min
    Weight with Facemask and Tubing:4 oz (0.1 kg)
    Input Connection:Oxygen therapy barb
    Operating Temperature:-18 to 50°C (0 to 122°F)
    Storage Temperature:-40 to 60°C (-40 to 140°F)
    Relative Humidity for Storage and Operating Use:15 to 95%
    Patient Face Mask Connection:22 mm

    [/read]

    Ordering Information

    [read more="Click here for Ordering Information" less="Read less"]

    CONFIGURATION 1 - CPAP system only

    01CV0211-CSO-Two Single-Use CPAP System (Large Adult) c/w Adult #5 Cuff Mask,
    Head Harness System, CPAP Device with Tubing
    Case/10
    01CV0212-CSO-Two Single-Use CPAP System (Adult) c/w Adult #4 Cuff Mask,
    Head Harness System, CPAP Device with Oxygen Supply Tubing
    Case/10
    01CV0213-CSO-Two Single-Use CPAP System (Child) c/w Child #3 Cuff Mask,
    Head Harness System, CPAP Device with Oxygen Supply Tubing
    Case/10

    CONFIGURATION 2 - CPAP system with Manometer

    01CV0217-CSO-Two Single-Use CPAP System (Large Adult) c/w Adult #5 Cuff Mask,
    Head Harness System, CPAP Device with Oxygen
    Supply Tubing and Pressure Manometer
    Case/10
    01CV0218-CSO-Two Single-Use CPAP System (Adult) c/w Adult #4 Cuff Mask,
    Head Harness System, CPAP Device with Oxygen Supply Tubing
    and Pressure Manometer
    Case/10
    01CV0219-CSO-Two Single-Use CPAP System (Child) c/w Child #3 Cuff Mask,
    Head Harness System, CPAP Device with Oxygen Supply Tubing
    and Pressure Manometer
    Case/10

    CONFIGURATION 3 - CPAP system with Manometer and Nebulizer

    01CV0224-CSO-Two CPAP System (Large Adult) with Nebulizer Kit c/w face mask (size 5) and
    head harness, pressure manometer, nebulizer with tubing and preset flow
    restrictor and “T” piece
    01CV0225-CSO-Two CPAP System (Adult) with Nebulizer Kit c/w face mask (size 4)
    and head harness, pressure manometer, nebulizer with tubing and preset
    flow restrictor and “T” piece
    01CV0226-CSO-Two CPAP System (Child) with Nebulizer Kit c/w face mask (size 3) and head harness,
    pressure manometer, nebulizer with tubing and preset flow restrictor and “T” piece

    Valve

    01CV0210-CSO-Two Replacement Single-Use High Visibility CPAP Flow Vector Valve Only Case/50

    [/read]

    Resources


  • CPAP Accessories

    Ordering Information

    01CV0220-CSO-Two Single-Use CPAP Nebulizer System c/w 6 L/min Flow Adapter,
    TPiece, Updraft Nebulizer with Oxygen Supply Tubing
    Case/10
    02RT1301-CSO-Two Single-Use CPAP Nebulizer T-PieceCase/10
    01CV8009-CSO-Two Replacement Neoprene Head Harness System  Case/5