Products

 

Immediate Care

Manual Ventilation – SMART BAG

  • SMART BAG® MO - Disposable

    Disposable Bag-Valve-Mask

     

    Improving Ventilation One Breath at a Time

    The SMART BAG® MO has been designed to allow the provision of consistent ventilations while almost completely eliminating the risks associated with conventional BVM ventilation. The unique actuating mechanism hidden inside the neck bushing of the SMART BAG® MO actually responds to the rescuer and the patient.

    By responding to the rescuer’s squeeze and release of the BVM, the SMART BAG® MO limits the excessive flow of gas into the patient’s airway, significantly reducing the risk of gastric insufflation by effectively lowering the airway pressure generated. In a normally compliant and resistant airway, the airway pressure is limited to below the esophageal sphincter opening pressure of 19 cm H2O.

    The response by the SMART BAG® MO is proportional to the rescuers squeeze. The harder the squeeze, the greater the restriction to flow. This alerts the rescuer to ease up on the squeeze, reducing the effort required, resulting in the airway pressure being kept to the minimum to achieve adequate ventilation. At no time is the flow of gas into the patient compromised by the SMART BAG® MO, allowing the rescuer to ventilate even the stiffest lung or most restrictive airway.

    To assist the rescuer a visual warning of incorrect ventilation technique of the SMART BAG® MO is provided. If the SMART BAG® MO is squeezed too hard, the SMART BAG® MO responds by closing the valve to lower the Flowrate. Should this occur, the “red pressure actuating indicator” moves to the forward position in the neck of the patient valve producing a visual warning of improper technique.

    If the patients airway is less compliant or more restrictive (as in patients with COPD or asthma), higher airway pressures will be required to provide adequate ventilation. In responding to this increased pressure required in the patient’s airway, the SMART BAG® MO decreases the resistance to flow from the BVM, balancing the pressure on either side of the valve. This allows the required pressure to be exerted by the rescuer on the patient’s airway to overcome the resistance / compliancy problem and provide adequate ventilations.

    The SMART BAG® MO is equipped with a Manual Override control to disable the action of the SMART Valve. Current research indicates that, for all patient conditions, the Manual Override control should NOT be used and the "SMART VALVE" should be left in the "Enabled" position. This recommendation maintains operation of the device in strict compliance with the current Guidelines for CPR and ECC as published by the American Heart Association and European Resuscitation Council.

    NOTE: To ensure correct operation of the manual override, do not switch into the disabled mode while squeezing the bag.

    Features:

    • Single Use.
    • Available in two models (Adult & Child).
    • Transparent Facemask allows for easy monitoring of skin color, signs of vomitus or body fluids.
    • Complete with Oxygen Reservoir System.
    • Controlled Flowrate.
    • Controlled Airway Pressure.
    • Controlled Ventilation.
    • Reduced Risk of Gastric Insufflation.

    The single-use O-Two Adult and PEDI Ventilation Timing Lights not only provide timing for the initiation of the breath but also indicate the duration of the ventilation by remaining illuminated for the duration of the inspiratory time. This provides safe, slow delivery of the breath. The off phase provides adequate expiration time to avoid breath stacking. Click here for more information.

    Specifications

    [read more="Click here for Specifications" less="Read less"]

    Operating Temperature Range-18°C to 50°C (0°F to 122°F)
    Storage Temperature Range-40°C to +60°C (-40°F to +140°F)
    Inspiratory Resistance3.3 cm H2O
    Expiratory Resistance2.2 cm H2O
    Dead space7.0 ml
    Adult Bag Volume1700 ml
    Child Bag Volume470 ml
    Reservoir Volume2700 ml

    (All specifications are subject to a tolerance of +/- 10%.)

    [/read]

    Ordering Information

    [read more="Click here for Ordering Information" less="Read less"]

    01BM3201-MO-CSSmart Bag® MO w/ manual override control, adult w/ cuffed mask,
    oxygen reservoir & tubing
    Case/12
    01BM3211-MO-CSSmart Bag® MO w/ manual override control, child w/ cuffed mask,
    oxygen reservoir & tubing
    Case/12
    01BM3200-MO-CSSmart Bag® MO w/ manual override control, adult w/ Universal
    Resuscitation mask, oxygen reservoir & tubing
    Case/12
    01BM3210-MO-CSSmart Bag® MO w/ manual override control, child w/ Universal
    Resuscitation mask, oxygen reservoir & tubing
    Case/12

    [/read]

    Resources


  • SMART BAG® MO - Reusable

    Silicone Autoclavable Bag-Valve-Mask

    Improving Ventilation One Breath at a Time

    The SMART BAG® MO Silicone Bag-Valve-Mask Resuscitator has been designed for Users who prefer Silicone and its autoclavable features. Provide consistent ventilations while almost completely eliminating the risks associated with conventional BVM ventilation. The unique actuating mechanism hidden inside the neck bushing of the SMART BAG® MO actually responds to the rescuer and the patient.

    Features

    • Autoclavable Silicone and reusable.
    • Available in two models (Adult & Child).
    • Transparent Universal Facemask allows for easy monitoring of skin color, signs of vomitus or body fluids.
    • Complete with Oxygen Reservoir System.
    • Controlled Flowrate.
    • Controlled Airway Pressure.
    • Controlled Ventilation.
    • Reduced Risk of Gastric Insufflation.

    The single-use O-Two Adult and PEDI Ventilation Timing Lights not only provide timing for the initiation of the breath but also indicate the duration of the ventilation by remaining illuminated for the duration of the inspiratory time. This provides safe, slow delivery of the breath. The off phase provides adequate expiration time to avoid breath stacking. Click here for more information.

    Specifications

    [read more="Click here for Specifications" less="Read less"]

    Operating Temperature Range-18°C to 50°C (0°F to 122°F)
    Storage Temperature Range-40°C to +60°C (-40°F to +140°F)
    Inspiratory Resistance3.3 cm H2O
    Expiratory Resistance2.2 cm H2O
    Dead space7.0 ml
    Adult Bag Volume1700 ml
    Child Bag Volume470 ml
    Reservoir Volume2700 ml

    (All specifications are subject to a tolerance of +/- 10%.)

    [/read]

    Ordering Information

    [read more="Click here for Ordering Information" less="Read less"]

    01BM3100-MOSmart Bag® MO w/ manual override control, adult w/ silicone mask,
    oxygen reservoir system in carton
    Each
    01BM3110-MOSmart Bag® MO w/ manual override control, child w/ silicone mask,
    oxygen reservoir system in a carton
    Each

    [/read]


  • SMART BAG Accessories


    Ordering Information

    01BM1000-CSAdult Ventilation Timing Light, individually packaged
    with Peel Back Adhesive Backing to attach to any
    Bag-Valve-Mask Resuscitator
    Case/50
    01BM1500-CSPedi Ventilation Timing Light is individually packaged
    with Peel Back Adhesive Backing to attach to any
    Bag-Valve-Mask Resuscitator
    Case/50
    17MP7020-CSDisposable PEEP divertercase/10
    10-55330-CSDisposable PEEP Valve 5 - 20 cm H2OCase/10
    17MP7110Cold chemical sterilizable PEEP diverterEach
    01CC8006Clear Plastic Storage Carrying Case
    (35mm x 15mm x 14mm)
    Each
  • Mini Ventilation Training Analyzer

    Manual Ventilation Training … Helps the Provider Eliminate Gastric Insufflation

    Students being trained in Bag-Valve-Mask ventilation are generally taught to ventilate until the chest rises. However, studies have shown that the delivery of incorrect rate and volumes is common. If the lungs are over-inflated or the delivered flow rate is too high, the high airway pressure generated will cause air to enter the stomach. In real life this can only be seen when the patient's abdomen distends and/or they begin to vomit.

    The Mini Ventilation Training Analyzer has been developed to demonstrate the correct ventilation technique when using a Bag-Valve-Mask resuscitator and the complications of gastric insufflation associated with incorrect technique.

    Base on a normal adult lung capacity, compliance, airway resistance and lower esophageal sphincter (LES) pressure, the Mini Ventilation Training Analyzer responds to the student's squeeze of the BVM like a real patient. If they squeeze the BVM too quickly or forcefully, the high pressure they generate (due to high air flow from the BVM) will cause air to enter the stomach through the calibrated Lower Esophageal Sphincter.

    The Mini Ventilation Training Analyzer is a unique tool that teaches real life skills while identifying real life problems. It can also be used for training in the proper use of manually triggered, gas powered resuscitators.

    • Small, lightweight and easily portable
    • Simple to assemble
    • Calibrated "Lower Esophageal Sphincter"
    • Simulated stomach
    • Calibrated Test Lung with compliance band and normal airway restriction
    • 22/22mm BVM connector
    • 30 mm "Stomach" connector
    • Unique lung connector
    • Instructions for use printed on the top label

    Ordering Information

    [read more="Click here for Ordering Information" less="Read less"]

    01TA1000Mini Ventilation Training Analyzer complete with Calibrated Stomach
    Simulator, Calibrated Lung Simulator, 22/22 mm BVM Connector,
    in Softpack Carrying Case with Shoulder Strap
    Each
    01TA1851Replacement Calibrated Test Lung c/w Compliance Band and Airway restrictorEach

    [/read]

    Download PDF Spec. Sheet