Award-winning, compact, low-flow, non-invasive ventilation for the respiratory distressed patient.

Continuous positive airway pressure (CPAP) has been proven to provide an effective method of treating respiratory distress from congestive heart failure (CHF). The use of CPAP is now being extended to other respiratory problems to provide symptom relief and avoid the need for intubation and ventilation of the patient as well as ICU admission.

The O-Two single-use open CPAP delivery system provides incredibly accurate CPAP delivery for such a compact device. By minimizing the pressure drop on inspiration and the peak pressure on expiration, the O-Two single-use open CPAP delivery system produces a more uniform CPAP pressure throughout the respiratory cycle. This provides a lower work of breathing for the patient when compared to other, commonly used, prehospital devices.

 

Easy to Use

An open system, the device allows unrestricted inspiratory flows, since the patient has access to ambient air.

Nebulizer treatments can be provided in-line, with the nebulizer positioned between the facemask and the CPAP unit.

 

A luer port is located on the device to attach a pressure gauge. However, the accuracy of the CPAP level at the fixed-flow settings noted on the device makes the use of a gauge unnecessary.

 

 

The ambient air intake port and the location of the in-line oxygen hose are designed to eliminate the possibility of accidental occlusion, removing the risk of barotrauma due to the patient or rescuer inadvertently blocking the port.

Ideal for the treatment of respiratory impaired patients suffering from a range of obstructive pulmonary diseases, the O-Two CPAP system is a simple, cost-effective alternative to invasive ventilation and possible intensive care admissions.

O-Two CPAP Advantages

The adjustment of the CPAP level is achieved by adjusting the output flow from your oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting.

Easy to Use

An open system, the device allows unrestricted inspiratory flows, since the patient has access to ambient air.

Nebulizer treatments can be provided in-line, with the nebulizer positioned between the facemask and the CPAP unit.

 

A luer port is located on the device to attach a pressure gauge. However, the accuracy of the CPAP level at the fixed-flow settings noted on the device makes the use of a gauge unnecessary.

 

 

The ambient air intake port and the location of the in-line oxygen hose are designed to eliminate the possibility of accidental occlusion, removing the risk of barotrauma due to the patient or rescuer inadvertently blocking the port.

Ideal for the treatment of respiratory impaired patients suffering from a range of obstructive pulmonary diseases, the O-Two CPAP system is a simple, cost-effective alternative to invasive ventilation and possible intensive care admissions.

O-Two CPAP Advantages

The adjustment of the CPAP level is achieved by adjusting the output flow from your oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting.

Specification Sheet

User Manual