Single-Use CPAP

CPAP-Logo

Award-winning Compact Low-flow Non-invasive ventilation for the respiratory distressed patient.

Continuous positive airway pressure (CPAP) has been proven to provide an effective method of treating respiratory distress from congestive heart failure (CHF). The use of CPAP is now being extended to other respiratory problems to provide symptom relief and avoid the need for intubation and ventilation of the patient as well as ICU admission.

The O-Two single-use open CPAP delivery system provides incredibly accurate CPAP delivery for such a compact device. By minimizing the pressure drop on inspiration and the peak pressure on expiration, the O-Two single-use open CPAP delivery system produces a more uniform CPAP pressure throughout the respiratory cycle. This provides a lower work of breathing for the patient when compared to other, commonly used, prehospital devices.

 

Easy to Use

An open system, the device allows unrestricted inspiratory flows, since the patient has access to ambient air.

Nebulizer treatments can be provided in-line, with the nebulizer positioned between the facemask and the CPAP unit.

 

A luer port is located on the device to attach a pressure gauge. However, the accuracy of the CPAP level at the fixed-flow settings noted on the device makes the use of a gauge unnecessary.

 

 

The ambient air intake port and the location of the in-line oxygen hose are designed to eliminate the possibility of accidental occlusion, removing the risk of barotrauma due to the patient or rescuer inadvertently blocking the port.

Ideal for the treatment of respiratory impaired patients suffering from a range of obstructive pulmonary diseases, the O-Two CPAP system is a simple, cost-effective alternative to invasive ventilation and possible intensive care admissions.

O-Two CPAP Advantages

The adjustment of the CPAP level is achieved by adjusting the output flow from your oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting.

Small and lightweight: complete system weights only  four onces (0.1kg)

Low oxygen consumption: Only 8-25 L/min for 5-25 cmH2O of CPAP

Simple to use: flow control adjustment to set CPAP level

Wide CPAP range: 1-25 cmH2O

No ambulance downtime in ER: simply attach to the ER oxygen supply

Decreased work of breathing: open circuit design imposes no work on the patient

Comfortable and secure head harness: soft, conforming Neoprene head harness

Small size: fits into existing jump bags and storage compartments

Cost effective: low purchase price and low oxygen consumption compared to other devices

Nebulizer kit: allows nebulized medications to be provided during CPAP treatment

Easy to Use

An open system, the device allows unrestricted inspiratory flows, since the patient has access to ambient air.

Nebulizer treatments can be provided in-line, with the nebulizer positioned between the facemask and the CPAP unit.



A luer port is located on the device to attach a pressure gauge. However, the accuracy of the CPAP level at the fixed-flow settings noted on the device makes the use of a gauge unnecessary.

 

 

The ambient air intake port and the location of the in-line oxygen hose are designed to eliminate the possibility of accidental occlusion, removing the risk of barotrauma due to the patient or rescuer inadvertently blocking the port.

Ideal for the treatment of respiratory impaired patients suffering from a range of obstructive pulmonary diseases, the O-Two CPAP system is a simple, cost-effective alternative to invasive ventilation and possible intensive care admissions.

O-Two CPAP Advantages

The adjustment of the CPAP level is achieved by adjusting the output flow from your oxygen therapy regulator or wall outlet. The setting selections noted on the device provide an accurate constant airway pressure at each flow setting.

Small and lightweight: complete system weights only  four onces (0.1kg)
Low oxygen consumption: Only 8-25 L/min for 5-25 cmH2O of CPAP

Simple to use: flow control adjustment to set CPAP level

Wide CPAP range: 1-25 cmH2O

No ambulance downtime in ER: simply attach to the ER oxygen supply

Decreased work of breathing: open circuit design imposes no work on the patient

Comfortable and secure head harness: soft, conforming Neoprene head harness

Small size: fits into existing jump bags and storage compartments

Cost effective: low purchase price and low oxygen consumption compared to other devices

Nebulizer kit: allows nebulized medications to be provided during CPAP treatment

Single-Use CPAP Specifications

CPAP range

1-25 cmH2O

Required flow rate

3-25 L/min

Dimensions (CPAP device only)

1.6” dia x 2.3” (40.6 mm dia x 58.3 mm)

Weight with Face Mask and Tubing

4 oz (0.1 kg)

Input Connection

Oxygen therapy barb

Patient Face Mask Connection

22ml

Operating Temperature

-18°C to 50°C (0°F to 122°F)

STORAGE Temperature

-40°C to 60°C (-40°F to 140°F)

Relative Humidity for Storage and Operating Use

15 to 95%

Single-Use CPAP Ordering Information

CPAP System

CPAP System with Manometer

01CV0217-CS

Single-Use CPAP (Large Adult) c/w Adult #5 Cuff Mask, Head Harness System, CPAP Device with Oxygen Supply Tubing and Pressure Manometer

Case/10

01CV0218-CS

Single-Use CPAP (Adult) c/w Adult #4 Cuff Mask, Head Harness System, CPAP Device with Oxygen Supply Tubing and Pressure Manometer

Case/10

01CV0219-CS

Single-Use CPAP (Child) c/w Child #3 Cuff Mask, Head Harness System, CPAP Device with Oxygen Supply Tubing and Pressure Manometer

Case/10

Replacement items

01CV0210-CS

O-Two Replacement Single-Use High Visibility CPAP Flow Vector Valve Only

Case/50

01CV0220-CS

O-Two Single-Use CPAP Nebulizer System c/w 6 L/min Flow Adapter, T-Piece, Updraft Nebulizer with Oxygen Supply Tubing

Case/10

02RT1301-CS

O-Two Single-Use CPAP Nebulizer T-Piece

Case/10

01CV8009-CS

O-Two Replacement Neoprene Head Harness System

Case/5

01CV0212-CS

O-Two Single-Use CPAP System (Adult) c/w Adult #4 Cuff Mask, Head Harness System, CPAP Device with Oxygen Supply Tubing

Case/10

Specification Sheet

User Manual

Brochure

Hands ON

The Sigle-Use CPAP

Hands ON

The Sigle-Use CPAP 2

Hands ON

Adding the Filter

Insights

CPAP Therapy

White Paper

CPAP in Prehospital Settings

White Paper

CPAP in COVID-19 patients with acute respiratory failure

ACCESSORIES