The Equinox® II Administration System is a simple, safe, efficient way of delivering pain relief during trauma, childbirth or painful procedures!
The Equinox® II Administration System is a rugged demand inhalation unit for the administration of 50% N2O/50% O2 analgesic gas mixture (Entonox®, ALnox® etc.) and was specifically designed for use in emergency and obstetric analgesia.
The system consists of a single stage pressure reducing regulator, a reinforced supply hose, a demand valve and a Universal patient oro-nasal mask. The Equinox® II Demand Valve delivers high flow rates with low triggering pressures, reducing the amount of effort required by the patient, to maintain the demanded flow.
The lightweight, demand valve incorporates a 360° Patient Valve Swivel Housing that is easily disassembled for cleaning. A Bleed Pin is included with the demand valve to effectively bleed the system of residual gas after use.
Virtually maintenance free, the durable the Equinox® II Administration System is a simple, safe and efficient way of delivering pain relief during trauma, childbirth or painful procedures.
Use of Filters
The use of a Breathing System Filter or BSF (commonly available in all hospitals) placed between the facemask or bite block, and the Equinox® II Demand Valve, removes the need to disassemble and disinfect the patient valve and diaphragm. Any pathogens present in the expired air are removed by the filter eliminating the risk of cross infection.
After each patient use, the Universal Facemask should be disinfected. A disposable facemask or bite block should be discarded. The outside of the demand valve body, gas supply tubing and patient valve can simply be wiped over with a hard surface disinfect in line with standard department protocols. Not only does the use of a BSF significantly reduce the downtime of the device between patients, it also limits the need for replacement parts (diaphragm and Patient Valve Housing) for the device.
NOTE: Only filters complying with ISO 23328 should be used.
Equinox® II Specifications
Demand Valve
(Minimum) Peak Flow rate
140 L/min
Exhalation Resistance
0 to 6 cmH2O @ 60 L/Min
Inhalation Resistance
0 to -6 cmH2O @ 60 L/Min
Input pressure
50 PSI
Initiation Pressure
-2 to -2.5 cmH2O
Patient connector
15/22 mm
Operating Temperature
-18oC to 50oC (0oF to 122oF)
Storage Temperature
-40o C to 60o C (-40o F to 140o F)
Weight
0.21 Kg (7.4 oz)
Dimensions WxDxH
Dia. 51mm x 81mm (2.0” x 3.2”)
Pressure Regulator
Inlet Connection
CGA 965 N2O/O2 Pin Indexed Yoke
Outlet Connector
5/8” Thread
Operating Pressure
500 -3000 PSI
Output Pressure
50 -60 PSI
Weight
0.45 Kg (1.0 lb)
Equinox® II Ordering Information
Demand Valve
Hose Configuration
01EQ7000E
Equinox® II Administration System c/w Regulator, Bleed Pin, 7 Foot Supply Hose, Demand Valve, Universal Face Mask, Cylinder Wrench
Each
Others Parts
01RE05S10-B
Equinox® II Brass Pin-Indexed Yoke Regulator with 1 x 5/8” Self Sealing DISS Outlets
Each
17MP1528
Equinox® II Diaphragm valve assembly
Each
17MP1535-CS
Equinox® II Anti-ntrainment ring
Case/10
17MP1100-90Deg
Equinox® II 90o Scavenger Adapter
Each
17MP1329
Equinox® II 7′ replacement hose
Each
This product has a two year warranty against manufacturers defects.
01EQ7001E
Equinox® II Demand Valve c/w 7 Foot Supply Hose, Universal Resuscitation Face Mask
Each
01RE05E40-B
Equinox® II Demand Valve c/w 7 Foot Supply Hose, Universal Resuscitation Face Mask
Each
01CV8028-CS
Single-Use 6 Foot Circuit with Scavenger Hose and Adapter with Mouthpiece
Case/10